Normal operation
This is what your outdoor unit looks like when the heat pump is doing its job. It pulls heat from the outside air and moves it inside, even on a cold Maryland morning, without the backup heat kicking in.
You went to turn up the heat and noticed the thermostat is set to "emergency heat" instead of its usual setting, or the light came on by itself. You did not touch that switch, and now you are wondering if the heat pump is broken or if someone in the house flipped it and does not remember. Either way, you want to know what it means before you decide what to do next.
A heat pump moves heat from the outside air into your house. When it cannot do that, the system falls back on a second heat source, usually electric resistance coils, to keep the house warm. Emergency heat is that backup running on its own, either because you switched to it or because the heat pump sensed a problem and stopped. In Maryland, where most homes heat with electricity and that power is not cheap, running on emergency heat for more than a day or two adds up fast, since resistance heat uses far more electricity than the heat pump does to produce the same warmth. If the thermostat is on emergency heat and you did not put it there, the outdoor unit likely needs a look before winter gets much colder.

This is what your outdoor unit looks like when the heat pump is doing its job. It pulls heat from the outside air and moves it inside, even on a cold Maryland morning, without the backup heat kicking in.

Dirty, clogged coils like these make the heat pump work harder to pull heat from the air. Once it can't keep up, the system can switch to emergency heat on its own, and that backup heat runs on electricity alone.




Emergency heat means the electric resistance coils are doing the work the outdoor unit usually does. Those coils heat the air directly, the way a toaster heats, and that takes a lot more electricity than a heat pump moving heat from outside. In Maryland, where most homes already heat with electricity, the difference shows up fast on the bill. A heat pump running normally might cost you a fraction of what the same hours on emergency heat will cost. If the switch stays on emergency heat for days while you wait on a repair, expect the next bill to reflect it.
A heat pump stuck on emergency heat is not drawing on the outdoor unit at all. That unit might have a frozen coil, a dead compressor, or a fan that will not spin, and none of those show up by looking at the thermostat. Leaving it alone and running on emergency heat all winter will not damage anything further, but it also will not fix what is wrong outside. The outdoor unit needs someone to look at it directly, since the problem that tripped the switch to emergency heat is still sitting out there unresolved.


A heat pump does not make heat the way a furnace does. It moves heat that is already in the outside air into your house, using refrigerant and a reversing valve to carry it across. That works even when it is cold outside, down to a point. Flip the thermostat to emergency heat and that whole process stops. The outdoor unit shuts off, and the only thing warming your house is a set of electric resistance coils, the same kind of heat as a space heater, just built into your air handler. Normally those coils only help out in short bursts. One of those bursts happens during defrost, when the outdoor coil ices up in cold, damp weather and the system has to pause and melt it off, using the coils to keep the air from blowing cold while it does. That is supposed to last a few minutes. If your system is stuck in emergency heat instead of cycling in and out of it, something has told it to stay there. A compressor that will not start, a reversing valve that will not shift, a fan motor that has quit, any of those can make the outdoor unit lock out and hand the whole job to the coils. An outdoor unit buried in ice can do the same thing, since it cannot pull heat from the air until it clears. Either way, the coils were built to help out for a few minutes, not run your whole house for days.


The thermostat calls for heat and checks the outdoor unit first.
A sensor reads outdoor coil temperature or ice buildup.
If the outdoor unit can't keep up, the switch sends power to the backup coils.
Electric resistance coils heat the air directly while the outdoor unit sits idle.
At 19.53 cents per kilowatt-hour, those electric coils add up fast on a Maryland bill. A heat pump stuck on emergency heat for even a few days can cost far more to run than the outdoor unit working the way it's supposed to.
EIA-861 2025 statewide residential average


Skip searching for a heat pump pro and answer a few questions instead.
You only hire the pro if you want to.

Leave emergency heat on by accident and the next electric bill will show it. Maryland winters run long enough that a heat pump stuck on backup coils for a couple of weeks can add real money to what you owe, not a few dollars. If the switch flipped because the outdoor unit has a problem, that problem doesn't go away on its own. It sits there costing you every day until someone looks at the unit itself.

Finding someone to look at the outdoor unit usually means searching around, calling a few contractors, explaining what the thermostat is doing each time, then sitting with quotes trying to tell them apart. You don't have to do any of that here. Answer a few questions about your heat pump and get matched with a contractor who works on these systems in Maryland, and they will reach out to you directly. That part of it is off your plate, even though the repair itself still has to happen.
Walk past a vent while the heat is running and feel the air. On emergency heat, it comes out hotter than you're used to, because the electric coils heat it directly instead of the heat pump moving warmth in gradually. The outdoor unit will be silent and still, even on a cold morning when you'd expect it working. Listen at the thermostat too. Some models click or hum differently when they switch over. If nobody in the house flipped that switch, check whether the outdoor unit is iced over or buried in snow, since that's often what triggers it. Left alone through a cold stretch, the coils will run nonstop trying to keep up, and your next electric bill will carry that weight.

This is what the outdoor unit looks like when it's doing the work it's supposed to. No dust caking the housing, no debris packed against the coils. Air moves through it freely, so it can pull heat from the outside air even on a cold morning without any help from the backup coils.

Dirt and grime built up like this block the airflow the outdoor unit needs to work. It starts struggling to pull heat from the air, and that struggle is often what pushes the thermostat to emergency heat in the first place, leaving the electric coils to carry the load instead.

A heat pump stuck on the backup coils doesn't stop heating your house. That's what makes it easy to miss. The rooms stay warm, the thermostat still reads the number you set, so nothing feels urgent. The only sign is the bill, and by the time that arrives you've already paid for however many days or weeks the coils did all the work alone.
If you caught this because the switch flipped on its own, that's worth paying attention to. It usually means the outdoor unit asked for help it shouldn't need yet, maybe ice building up on the coil, maybe something keeping it from pulling heat the way it should. A contractor who works on heat pumps in Maryland can look at the outdoor unit and tell you whether it's something small or something that'll keep tripping the switch back to emergency heat all winter. That's less back and forth than you'd expect, since you'd only need to describe the problem once and get matched with someone who already knows what to check first.


Summer here isn't the season that matters for emergency heat, but it tells you something about your heat pump anyway. Averaged across Maryland homes, the summer dew point runs 64°F, heavy enough that the same outdoor unit working to cool your house in July is the one that's supposed to be pulling heat from that air in January. It's one machine doing both jobs. When the switch gets stuck on emergency heat, that outdoor unit sits idle through the cold months, and the electric coils take over completely. Figure from NOAA climate normals for Maryland.
NASA POWER T2MDEW county cells weighted by homes
Emergency heat on a Maryland heat pump means the outdoor unit has stopped and the electric coils are carrying the house alone. That's fine for a night or two if the outdoor unit iced up in a cold snap. It's not fine for weeks, because those coils cost more to run every hour they're on, and the switch doesn't flip itself back. A thermostat stuck there is usually telling you something: a dirty outdoor coil, a failed sensor, a unit that can't keep up anymore. Instead of searching through contractors, calling a few, explaining the thermostat and the bill and the coils to each one, then sorting through whatever quotes come back, you can get matched with a contractor who works on heat pumps like yours and let them reach out to you. You already know what you're seeing. The next step is getting someone out to look at the unit itself.

Asking costs nothing, and the choice to hire stays yours.
A thermostat stuck on emergency heat won't fix itself. Getting the outdoor unit looked at means you skip searching for contractors, calling around, and explaining the same problem twice, and get matched with someone who can take a look at what's keeping it from running.