May is the month to catch a weak system
Cooling in Talbot County starts in June and runs through September. May is when a system that struggled last summer shows it before the heat arrives.
Takes about a minute. No obligation.
Cooling in Talbot County starts in June and runs through September. May is when a system that struggled last summer shows it before the heat arrives.
A capacitor or contactor that barely made it through last September often fails in the first real heat of June, when the system runs longest without a break.

NOAA nClimDiv, 1991–2020 normals
Summers here run June through September, with afternoon highs averaging 86.
Four months of steady work is normal load, not strain, so a system that's struggling has a part problem, not a weather problem.




If your AC came with a house built in 1983 or later, that system probably has years left in it. A repair is worth paying for. Before you write off an older unit as too old to fix, find out when it was actually put in. Plenty of systems get replaced partway through a house's life, so the age of the home doesn't tell you the age of the AC. Ask the contractor to check the manufacture date on the unit itself before deciding anything.
A system that's low on refrigerant or struggling to start runs longer to do the same job, and at Maryland's rates that shows up on the bill every month it's not fixed. Getting the actual part diagnosed now stops the waste instead of paying for it all summer.
Find a contractor
Before anyone comes out, check the simple things first. Look at the thermostat and make sure it's set to cool and set below room temperature, not just sitting there on a schedule that hasn't kicked in yet. Go to the breaker panel and check that the breaker for the outdoor unit hasn't tripped. Check the air filter. A filter clogged with dust chokes off airflow, and the system can ice up the coil trying to breathe through it. If you can get to the outdoor unit, look for anything blocking it, leaves, grass clippings, a branch, and clear a space around it. Check the vents inside the house to make sure none of them got closed or blocked by furniture. If the system is running but the air isn't cold, that's usually not something you can fix yourself, it points to a refrigerant or compressor problem that needs a gauge set to diagnose. If you see ice on the indoor coil or the line running outside, turn the system off and let it thaw completely before anyone touches it further, running it iced up can damage the compressor. None of this tells you what's wrong inside the unit, but it rules out the things that aren't worth paying a service call for.
If the air coming out of the vents is warm or barely cool, the compressor outside isn't doing its job or the refrigerant charge is low. This isn't a filter or a thermostat setting. It takes gauges to find out which one it is, and it won't fix itself by running longer.
A grinding or squealing sound usually means a motor bearing is wearing out. A loud bang on startup often means a part has come loose inside the compressor. Either way, the system is still running, which is why people keep using it, but the noise only gets worse until that part is replaced.
Estimates for a typical Talbot County home, compared with an older unit built to the previous federal minimum, from EIA household energy data, Maryland fuel prices and NOAA climate normals. Your home will differ.
Repair makes sense when a part like a capacitor or contactor has failed.
Replacement makes sense when the compressor has failed or the system uses R-22 refrigerant, which is no longer made.
A diagnostic visit starts with gauges on the refrigerant lines. The tech reads the pressure on both the high side and the low side. That reading shows whether the charge is right, whether the compressor is doing its job, and whether something is restricting the line. Next comes electrical testing. The capacitor gets checked under load, because a weak one can still show voltage sitting still and fail the moment the compressor tries to start. The contactor gets checked for pitting, since burnt contacts cause the kind of intermittent starting problems that feel random from inside the house. If the complaint is weak airflow, the tech checks static pressure across the coil and the blower instead of just glancing at the filter. Whatever turns up gets explained before any part is replaced, so the repair matches what actually failed.